1.
Rev. odontol. UNESP (Online) ; 48: e20180123, 2019. tab, graf, ilus
Article in English | LILACS, BBO | ID: biblio-1014404

ABSTRACT

Abstract Introduction For complete rehabilitation of fully edentulous mandibles, the option for immediate loading determines the use of temporary prostheses that splint the installed implants. Although temporary prostheses with reinforcement provide rehabilitations with biomechanical benefits, the non-adoption of this recommendation coexists in different studies on immediate restorations. Objective This study evaluates a type of prosthesis to restore jaws by the all-on-four concept. Material and method: The mechanical behavior of prostheses with the modified framework was evaluated in vitro, under a cantilever mechanical unilateral bending test. Two representative groups were included in the all-on-four concept, with a G1 test group (n = 10) containing modified frameworks and a G2 control group (n = 10) that included full acrylic prostheses. The samples were submitted to thermal cycling with 500 cycles (5° ± 2 °C for 30 s, and 55° ± 2° for 30 s) and to the mechanical bending test on the cantilever. Result The Mann-Whitney test revealed a significant difference between G1 and G2 (p <0.001). In the descriptive evaluation, G1 averaged 830.50 N until the initial resin fracture, while the control group presented a mean of 403.58N. The maximum resistance until complete fracture was recorded in G1, with a mean of 903.03N, while in G2, a mean of 435.20N was recorded. The linear vertical component of the flexion was 0.68 mm and 0.39 mm until the initial fracture of the bar, respectively for G1 and G2. Conclusion The modified framework for the all-on-four protocol determined better mechanical performance when compared to the same full acrylic prosthesis model.


Resumo Introdução Para reabilitação de mandíbulas totalmente edêntulas, a opção por carga imediata determina a utilização de próteses provisórias que esplintem os implantes instalados. Apesar de provisórias com reforço proverem as reabilitações com benefícios biomecânicos, a não adoção desta indicação coexiste em diferentes estudos sobre restaurações imediatas. Objetivo Este estudo avaliou um tipo de prótese para reabilitar mandíbulas pelo conceito "all-on-four". Material e método: Foi avaliado, in-vitro, o comportamento mecânico de próteses com a infraestrutura modificada, sob ensaio mecânico de flexão unilateral em cantilever. Foram avaliados dois grupos representativos para o conceito "all-on-four", sendo um grupo teste G1 (n = 10) contendo próteses com infraestrutura modificada e outro controle G2 (n = 10) que incluiu próteses totalmente acrílicas. As amostras foram submetidas à ciclagem térmica com 500 ciclos (5° ± 2 °C por 30 segundos e 55° ± 2 °C pelo mesmo tempo) e submetidas ao ensaio mecânico à flexão sobre o cantilever. Resultado O teste de Mann-Whitney revelou diferença significativa entre G1 e G2 (p<0,001). Na avaliação descritiva, G1 mostrou média de 830,50 N até a fratura inicial em resina e o grupo controle apresentou média de 403,58N. A resistência máxima até a fratura completa foi de 903,03 N para G1 e para G2 de 435,20 N. O componente vertical linear de flexão foi 0,68 mm e 0,39 mm até a fratura inicial da barra, respectivamente para G1 e G2. Conclusão A infraestrutura modificada para o protocolo "all-on-four" proporcionou melhor desempenho mecânico quando comparado ao mesmo modelo de prótese totalmente acrílico.


Subject(s)
Biomechanical Phenomena , Immediate Dental Implant Loading , Mandible , In Vitro Techniques , Dental Implants , Denture, Partial, Temporary
2.
Rev. odontol. UNESP (Online) ; 48: e20190010, 2019. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1043187

ABSTRACT

Resumo Introdução A cimentação adesiva, com cerâmicas puras, é um passo relevante no estabelecimento da longevidade de trabalhos protéticos, sendo estes os melhores materiais utilizados para a reposição de dentes perdidos, de forma a reabilitar o sorriso. O sistema cerâmico de zircônia não se beneficia do tratamento com ácidos e necessita de diferentes métodos para tratar sua superfície, visando à efetividade na união adesiva. Objetivo Avaliar os resultados de diferentes técnicas de jateamento e aplicação de agente de união desenvolvidas para metais e cerâmica de zircônia (Ceramill ZI®), por meio de ensaio de tração, em dois diferentes tratamentos de superfície. Material e método Foram preparadas 20 amostras de Ceramill Zi® (n = 20), em forma de cilindro, e unidas entre si por meio do cimento resinoso (Multilink®), formando 10 espécimes (n = 10). Formaram-se sete grupos experimentais com os mesmos 10 espécimes e estes receberam dois tratamentos de superfície diferentes: abrasão e aplicação de agentes silânicos de união. Resultado A análise estatística mostrou diferenças significativas na resistência à fratura dos espécimes silicatizados com Rocatec®. Os valores de resistência de união à tração, mensurados em MPa, dos grupos 1 a 7, foram, respectivamente: 2,27; 4,48; 8,06; 8,32; 9,15; 10,56 e 10,70. As médias entre os grupos se apresentam estatisticamente significantes, exceto entre os grupos 3 e 4 e entre 6 e 7. Conclusão Os resultados mostraram que o tratamento da superfície cerâmica baseado no método de silicatização promoveu melhor união nos ensaios com Ceramill ZI® e cimentados com Multilink®.


Abstract Introduction Adhesive cementation, with pure ceramics, is a relevant step in establishing the longevity of prosthetic works. Being these, the best materials used for the replacement of lost teeth, in order to rehabilitate the smile. The ceramic zirconia system does not benefit from the treatment and planning needs for its surface, effectively in adhesive therapy. Objective Evaluate the results of different blasting techniques and application of bonding agent for metals and ceramics (Ceramill ZI®) by means of a tensile test in two different surface treatments. Material and method Twenty samples of Ceramill Zi® (n = 20), cylindrical and joined with resin cooling (Multilink®), were prepared, forming 10 specimens (n ​​= 10). The first 10 ingredients were formed by 7 experimental groups and they received 2 surface problems: abrasion and application of silane bonding agents. Result The research resulted in fracture resistance of Rocatec® silica specimens. The values ​​of tensile strength, measured in MPa, of groups 1 to 7, were: 2.27; 4.48; 8.06; 8.32; 9.15; 10.56 and 10.70. We observe how to enter the groups are statistically significant, except between groups 3 and 4 and between 6 and 7. Conclusion The results of the ceramic surface treatment were based on no silicate method, promoting the union of results with Ceramill ZI® and cemented with Multilink®.


Subject(s)
Ceramics , Cementation , Air Abrasion, Dental
3.
Braz. dent. j ; 29(2): 133-139, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-951524

ABSTRACT

Abstract This controlled randomized clinical trial evaluated the effect of associating at-home and in-office bleaching procedures on tooth sensitivity (TS) and bleaching effectiveness. Forty patients subjected to on session of in-office bleaching with 38% peroxide hydrogen. Subsequently, the patients were randomly allocated to receive a second session of in-office bleaching or to use a tray containing 10% carbamide peroxide delivered during 7 consecutive days. The worst TS score reported during or after each bleaching procedure was recorded using a verbal rating scale and TS risk (score different from 0) was calculated. Color changes were measured 7 days after each in-office session (for patients receiving in-office procedures only) or after the end of at-home bleaching (for the combined protocol), and 6 months after the last procedure for both bleaching protocols. Color was assessed by a spectrophotometer and by color match with the Vita Classical and Bleach guide scales. Statistical analyses were carried out to assess possible differences between the protocols regarding the outcomes and to analyze the effect of time of assessment on color changes. The bleaching protocol did not affect the risk for and the maximum level of TS reported, irrespective of the time of assessment. In the color evaluation, the bleaching protocol also did not affect the ultimate tooth color. In conclusion, after one in-office bleaching session, there was no difference in bleaching effectiveness and TS between performing a second in-office session and associating it with 1-week at-home bleaching.


Resumo Este ensaio clínico controlado e randomizado avaliou o efeito da associação de procedimentos de clareamento caseiro e de consultório na sensibilidade dental (SD) e efetividade clareadora. Quarenta pacientes receberam uma sessão de clareamento de consultório com peróxido de hidrogênio a 38%. Em seguida, os pacientes foram aleatoriamente alocados para receberem uma segunda sessão de clareamento de consultório ou para usar uma moldeira com peróxido de carbamida a 10% por 7 dias consecutivos. O pior score de SD relatada durante ou após cada procedimento clareador foi mensurado usando uma escala verbal, e o risco a SD (escore diferente de 0) foi calculado. Mudança de cor foi mensurada 7 dias após cada sessão de clareamento de consultório (para paciente submetidos a apenas procedimentos de consultório) ou após o fim do clareamento de caseiro (para o protocolo combinado) e 6 meses após o último procedimento clareador para os dois protocolos de clareamento. A cor foi mensurada através de um espectrofotômetro e pelo uso das escalas Vita Clássica e Bleach guide. As análises estatísticas foram realizadas para verificar possíveis diferenças em relação aos desfechos e para analisar o efeito do momento da mensuração nas mudanças de cor. O protocolo clareador não afetou o risco e o nível máximo de SD relatado, independentemente do tempo de avaliação. Na avaliação de cor, o protocolo clareador também não afetou a cor final dos dentes. Como conclusão, após uma sessão de clareamento de consultório, não há diferença na efetividade clareadora e na SD em realizar uma segunda sessão de consultório ou associá-la com uma semana de clareamento caseiro.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Self Care , Tooth Bleaching/methods , Dental Health Services , Dental Offices , Dentin Sensitivity , Spectrophotometry/methods , Single-Blind Method , Color , Hydrogen Peroxide/administration & dosage
4.
Int. j. odontostomatol. (Print) ; 11(4): 487-493, dic. 2017. tab, graf
Article in English | LILACS | ID: biblio-893293

ABSTRACT

ABSTRACT: The objective of this study was to verify the influence of the use of Class II intermaxillary elastics on centric relation (CR) to centric occlusion (CO) occlusal discrepancy. A total of 30 patients had been at the contention stage for at least three months were divided in two groups: G1 - 15 had been submitted to intramaxillary orthodontic mechanics only, and G2 - 15 had used Class II intermaxillary elastics. Distances of horizontal and vertical overlap and the distance or coincidence of the mandibular dental midline in relation to the maxillary midline were measured in CR and CO positions. Intergroup comparisons were performed using the Mann-Whitney test. No statistically significant differences (P>0.05) were found between G1 and G2. Both in the horizontal and vertical directions, these discrepancies were smaller than or equal to 1mm in 96.66 % of the patients. In the transverse plane, there was no discrepancy in 63.33 % of the patients, and in 33.33 % these discrepancies were equal to 0.5 mm. The use of Class II elastic didn't be capable of increasing the occlusal discrepancies between CR and CO.


RESUMEN: El objetivo de este estudio fue verificar la influencia del uso de los elásticos intermaxilares Clase II en la discrepancia oclusal entre la relación céntrica (RC) y la oclusión céntrica (OC). Un total de 30 pacientes que permanecieron en la fase de contención durante al menos tres meses se dividieron en dos grupos: G1 - 15 fueron sometidos solamente a la mecánica ortodóncica intramaxilar, y G2 - 15 habían utilizado elásticos de clase II intermaxilar. Se midieron las distancias de traslapo horizontal y vertical y la distancia o coincidencia de la línea mediana dentaria mandibular con respecto a la línea mediana maxilar en las posiciones RC y OC. Las comparaciones entre grupos se realizaron mediante la prueba de Mann-Whitney. No se encontraron diferencias estadísticamente significativas (P> 0.05) entre G1 y G2. Tanto en las direcciones horizontal como vertical, estas discrepancias fueron menores o iguales a 1 mm en el 96,66 % de los pacientes. En el plano transversal, no hubo discrepancia en el 63,33 % de los pacientes, y en un 33,33 % estas discrepancias fueron iguales a 0,5 mm. El uso de la clase II elástica no logró aumentar las discrepancias entre RC y OC.


Subject(s)
Humans , Male , Female , Child , Adult , Orthodontic Appliances, Removable , Malocclusion/therapy , Malocclusion, Angle Class II/therapy , Orthodontics, Corrective/instrumentation , Orthodontics, Corrective/methods , Tooth Movement Techniques , Statistics, Nonparametric , Ethics Committees, Research , Jaw Relation Record/instrumentation , Jaw Relation Record/methods
5.
Rev. CEFAC ; 19(1): 54-62, jan.-fev. 2017. tab, graf
Article in Portuguese | LILACS | ID: biblio-842588

ABSTRACT

RESUMO Objetivo: o objetivo deste estudo foi avaliar a acurácia das radiografias transcranianas (TRANS) convencionais na identificação das alterações morfológicas nos côndilos mandibulares. Métodos: a amostra consistiu em 36 côndilos mandibulares, obtidos a partir de 18 crânios secos humanos, aleatoriamente selecionados, sem identificação de idade, gênero ou etnia. Três especialistas em radiologia oral examinaram as TRANS para identificar possíveis alterações nos côndilos. Um quarto examinador realizou o exame macroscópico, que foi considerado o padrão ouro do estudo. As imagens das TRANS e os exames macroscópico foram classificados como (1) côndilos com alteração ou (0) côndilos sem alteração. A análise estatística foi realizada através do teste X 2 e da curva ROC (receiver operator characteristic). O teste Kappa intra e interexaminadores foi realizado para os examinadores 1 a 3. Resultados: o teste X2 mostrou uma associação estatisticamente significativa entre as alterações no côndilo vistas nas imagens TRANS e a presença de alterações macroscópicas (p ( 0,05). A área sob a curva ROC foi de 0,83, com 96% de sensibilidade e 70% de especificidade. O valor Kappa para a concordância intraobservador foi de 0,78, enquanto que a concordância interexaminador foi de 0,71. Conclusão: o uso de radiografias transcranianas apresentou-se como método eficaz para a detecção de alterações morfológicas no côndilo mandibular.


ABSTRACT Purpose: to evaluate the accuracy of conventional transcranial radiographs (TRANS) to identify morphological changes in mandibular condyles. Methods: the sample consisted of 36 mandibular condyles, obtained from 18, randomly selected, dried human skulls, without the identification of age, gender, or ethnicity. Three experts in dental radiology examined the TRANS to identify possible changes in the condyles. The fourth examiner performed the macroscopic examination, which was considered the gold standard of the study. The condyles in both TRANS images and macroscopic examinations were classified as mandibular condyles with change (1) or no change (0). Statistical analyses were performed using the X 2 and the receiver operating characteristic (ROC) curve. Kappa intra- and interobserver tests were performed for examiners 1 to 3. Results: the X2 test showed a statistically significant association between changes in the condyle in the TRANS images and the presence of macroscopic changes in the condyle (p ( 0.05). The area under the curve was 0.83, with 96% sensitivity and 70% specificity. The weighted kappa value for intraobserver agreement was 0.78, while the interobserver agreement was 0.71. Conclusion: the use of TRANS proved to be an effective method to detect morphological changes in the mandibular condyle.

6.
Rev. CEFAC ; 18(3): 801-806, graf
Article in Portuguese | LILACS | ID: lil-787752

ABSTRACT

RESUMO: A articulação temporomandibular é uma das mais complexas do corpo humano sendo o processo condilar responsável pela expressão do crescimento mandibular. A hipoplasia condilar é caracterizada por uma formação defeituosa do processo condilar. A otite média aguda é um processo inflamatório, desencadeada a partir de infecções das fossas nasais, cavidades paranasais e rinofaringe, propagadas por meio da tuba auditiva. No caso apresentado, a paciente apresentava assimetria facial desde o primeiro ano de vida, além de recorrentes casos de otite justamente nos estágios iniciais do fechamento da sutura temporotimpânica e do forame de Huschke o que facilitaria a disseminação dessa infecção otológica o que comprometeria o desenvolvimento do côndilo resultando na hipoplasia identificada, somente do lado direito. Assim, os profissionais que atuam na região da articulação temporomandibular e ouvido devem ter o conhecimento da existência e das implicações clínicas do forame de Huschke para um diagnóstico precoce e evitar o desenvolvimento das assimetrias faciais nos casos em que esta apresenta associação com sinais clínicos de infecção das áreas afetadas, restabelecendo função, estética e o estado psicológico do paciente.


ABSTRACT: The temporomandibular joint is one of the most complex of the human body and the condylar process is responsible for the expression of mandibular growth. The condylar hypoplasia is characterized by a defective formation of the condylar process. The acute otitis media is an inflammatory process, triggered from infections of the nasal cavity, paranasal sinuses and, nasopharynx, propagated through the Eustachian tube. In the presented case, the patient had facial asymmetry since the first year of life, and recurring cases of otitis just in the early stages of closing the temporal tympanic suture and in the foramen of Huschke, which would facilitate the dissemination of this ear infection which would undermine the development of condyle resulting in hypoplasia identified, only in the right side. Thus, professionals who work in temporomandibular joint and ear regions must have knowledge of the existence and clinical implications of the foramen of Huschke for early diagnosis and prevent the development of facial asymmetry where this association presents with clinical signs of infection of the affected areas, restoring function, aesthetic and, psychological state of the patient.

7.
Rev. CEFAC ; 18(1): 27-32, jan.-fev. 2016. tab
Article in English | LILACS | ID: lil-775662

ABSTRACT

RESUMO Objetivo: mensurar o nível de pressão sonora emitido pelo aparelho de ressonância magnética em funcionamento e verificar as sensações auditivas descritas pelos indivíduos submetidos a este exame após a realização do mesmo. Métodos: foi realizada a mensuração do ruído produzido, durante a aquisição das imagens, por meio de um medidor de nível de pressão sonora (decibelímetro) e a aplicação de um questionário com a finalidade de verificar as sensações auditivas apresentadas por estes indivíduos após a realização do exame. Tal procedimento foi aplicado a 60 indivíduos submetidos ao exame de ressonância magnética do crânio. Resultados: o nível de pressão sonora média apresentada durante a realização do exame foi inferior ao nível de intensidade considerado como risco para lesões auditivas. No entanto, sensações como zumbido, ansiedade, plenitude auricular e alívio após o término do exame foram citados pelos indivíduos após a execução do mesmo. Conclusão: é pertinente o uso de protetores auriculares como medida preventiva para o controle do nível de ruído que atinge a cóclea do indivíduo, minimizando desta forma os efeitos físicos e psicossociais decorrentes da exposição ao ruído.


ABSTRACT Purpose: to measure the sound pressure level emitted by the magnetic resonance imaging in operation and check the auditory sensations described by individuals submitted to this examination after it has been carried out. Methods: the measurement of the deep noise was conducted during image formation in this examination, by means of sound pressure level meter (decibel meter) and the application of a questionnaire for the purpose of checking the hearing sensations presented by those individuals after the exam has been carried out. This procedure was applied to sixty individuals submitted to a magnetic resonance imaging of the skull. Results: it was found that the average of sound pressure level presented while the examination was carried out was lower than the level of intensity considered being a risk for auditory damages. However sensations like tinnitus, anxiety, auricular plenitude and relief after the end of the examination were mentioned by the individuals after it had been carried out. Conclusion: the use of hearing protectors is relevant as a preventive measure for controlling the level of noise that affects the individual's cochlea, thus minimizing the physical and psycho-social effects resulting from noise exposure.

8.
Braz. j. oral sci ; 14(3): 209-213, July-Sept. 2015. graf
Article in English | LILACS, BBO | ID: lil-770527

ABSTRACT

Abstract Aim: To investigate whether the removal and reseating of the abutment influences the retention of Morse taper implant system. Methods: Two Morse taper implant systems were selected: Bicon Dental ImplantTM system (Bicon, LLC, Boston, MA, USA) and Kopp Implant(r) system (Kopp(r), Curitiba, PR, Brazil). In both systems, the abutment is connected to the implant with a locking taper. To seat the abutment, the same vertical force was applied in both systems. It was measured the compressive force necessary to engage effectively the locking taper connection and the tensile force to displace it. Results: The compressive force was determined by four activations in each abutment-implant set, and the sum of these forces was 21 N and 17 N in the BiconTM and Kopp(r) systems, respectively. Next, a tensile test was performed, revealing that the BiconTM system presented a 208 N resistance, whereas it was 194 N in the Kopp(r) system. Other three rounds of compression and tensile loads were applied, removing and reseating the abutment. We obtained the following tensile values: 367 N, 500 N and 756 N in the BiconTM System and 336 N, 360 N and 420 N in the Kopp(r) system. Conclusions: When the sets were subjected to repeated rounds of compressive and tensile forces, displacing and reseating the abutment, the tensile value increased.


Subject(s)
Tensile Strength , Dental Implants , Compressive Strength , Dental Implant-Abutment Design
9.
Pesqui. bras. odontopediatria clín. integr ; 15(1): 243-252, 2015. tab, graf
Article in English | LILACS | ID: lil-796369

ABSTRACT

To assess the sealing capacity of different dental cements regarding apical microleakage on teeth with prefabricated posts. Material and Methods:Forty-eight single-rooted teeth were selectedand, after having their coronal part removed at 10mm standard, underwent endodontic cleaning and preparation. The space for the post was prepared with # 3 Largo bur at 7 mm standard value. The study included the following groups: Group I, post prefabricated with # 1 intracanal glass fiber cemented with zinc phosphate cement (n = 12); Group II, post prefabricated with # 1 intracanal glass fiber cemented with conventional glass ionomer cement, Vidrion C (n = 12); Group III, post prefabricated with # 1 intracanal glass fiber cemented with chemical action resin cement, Multilink (n = 12). Two groups of six teeth each were also included, one as negative control group and the other as positive control. After cementing, teeth were tested through a dual-chamber experimental model, using Enterococcus Faecalis for apical contamination. Results:The control groups behaved as expected: positive control group with total contamination in 11 days and negative control group without any contaminated specimen within observation time of 60 days. Group I showed microleakage in all specimens for up to 29 days (100%)...


Group II and Group III showed microleakage in 50 and 49 specimens (83.33% and 75%) respectively along the research time of 60 days. Group 1 showed microleakage in all specimens for up to 29 days (100%). Group 2 and Group 3 showed microleakage in 50 and 49 specimens (83.33% and 75%) respectively along the research time of 60 days. The Log-Rank test showed differences between Groups 1 and 2 (p<0.05) and between Groups 1and 3 (p<0.05). However, there was no difference between Groups 2 and 3 (p> 0.05). The results showed higher delay in bacterial infiltration in Groups 2 and 3 when compared to Group 1.Conclusion:No cement completely prevented infiltration during the experimental period. Zinc phosphate cement had the lowest apical sealing capacity while glass ionomer cement and resin cement showed similar results...


Subject(s)
Humans , Dental Cements/chemistry , Glass Ionomer Cements , Dental Leakage , Tooth Apex/microbiology , Brazil , Endodontics/methods
10.
Rev. CEFAC ; 16(6): 2053-2059, Nov-Dec/2014. graf
Article in Portuguese | LILACS | ID: lil-736249

ABSTRACT

A tomografia computadorizada desempenha um papel importante no diagnóstico de anomalias e condições patológicas da ATM, permitindo a visualização completa da região articular, fornecendo um diagnóstico mais preciso. Para avaliação das imagens tomográficas é necessário que o profissional tenha o conhecimento da anatomia seccional da região articular, para que o mesmo reconheça as alterações estruturais. Assim, foi exposto e descrito neste trabalho as características tomográficas de normalidade, alterações morfológicas e condições patológicas mais encontradas na região da articulação temporomandibular. Sendo a tomografia computadorizada um exame de imagem superior aos métodos convencionais de imagem para ATM, pois permite uma visualização tridimensional adequada e apurada de todos os detalhes ósseos sem a limitação das sobreposições, fornecendo o tamanho e formato real das estruturas anatômicas, alterações morfológicas e condições patológicas.


The computed tomography plays an important role in the diagnosis of anomalies and pathological conditions of the TMJ, providing a complete visualization of joint region, providing a more accurate diagnosis. For evaluation of the images is necessary to the professional the knowledge of sectional anatomy of the joint region, so he can recognize the structural changes. Therefore, it was explained and described in this study the characteristics of normal CT, morphological and pathological conditions commonly found in the region of the temporomandibular joint. The Computed tomography is an imaging exam superior than the conventional imaging exam for TMJ, because it allows an adequate and accurate three-dimensional visualization of all details of the bone, without the limitation of overlap, providing the real size and shape of the anatomical structures, morphological changes and pathological conditions.

11.
ImplantNews ; 10(1): 31-38, 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-731422

ABSTRACT

Em algumas situações clínicas em que pacientes parcialmente edêntulos apresentam a indicação para prótese fixa de cinco elementos dentoimplantossuportada, o implante pode se tornar algumas vezes o pilar intermediário dessa prótese. Esse tipo de prótese deve ser feito com cautela, tendo em vista possíveis complicações biomecânicas, pelas diferenças de mobilidade entre dente e implante e pela diferença na absorção e na distribuição das cargas funcionais. O objetivo desse trabalho foi analisar, por meio do método dos elementos finitos (MEF), as tensões geradas em uma prótese fixa dentoimplantossuportada de cinco elementos, modelada pelo programa computacional Ansys Revisão 5.7, sendo composta por dois dentes como pilares terminais, dois pônticos e um implante como pilar intermediário unidos de forma rígida. Foi aplicada uma carga vertical com valor nominal de 100 Newtons (N), distribuída uniformemente nas superfícies oclusais dos dentes posteriores. Pôde-se observar em uma análise qualitativa que o maior deslocamento da prótese no sentido oclusogengival foi na região dos pônticos, com valor máximo de deslocamento de 6,4 micrometros (µm). A tensão equivalente de Von Mises SEQV foi de 77,4 Megapascal (MPa) notando uma distribuição de tensões semelhante por toda infraestrutura metálica, na região entre as coroas protéticas. Concluiu-se que a infraestrutura metálica rígida exerce papel fundamental na distribuição e absorção das tensões e no deslocamento do conjunto protético e o implante intermediário não atua como fulcro de uma alavanca Classe I.


In some clinical situations, partially edentulous patients can have indication for a five-element implant-supported prosthesis, with one of those implants being the pier abutment. This type of prosthesis should be constructed with caution, because of possible biomechanical uncertainties, due to different displacement behaviors and the distribution of the functional loads involved in the process. The aim of this work was to analyze by Finite Element Method (FEM) the global behavior of stresses and displacements involved in a tooth-implant-supported fixed prosthesis with five elements, having two teeth as terminal abutments, two bridges and an implant working as an intermediate abutment. The Ansys 5.7 program has been used as a computational tool. A nominal vertical load of 100 N has been applied, uniformly distributed, on the occlusive surfaces in the posterior teeth. It is possible to conclude, in a qualitative analysis, that the prosthesis showed a higher displacement in the occlusion-gingival direction of the bridges, with a value around 6,4 µm. The equivalent Von Misses stresses (SEQV) showed a maximum value of 77,4 MPa in the metallic bar among the prosthetic crowns. It can be concluded that the infra-structure has an important function in the distribution and absorption of stresses and displacements of the whole prosthetic set and the implant did not work as pier abutment.


Subject(s)
Humans , Dental Implantation , Denture, Partial, Fixed , Tooth
12.
Dental press j. orthod. (Impr.) ; 17(3): 58-63, May-June 2012. ilus
Article in English | LILACS | ID: lil-646350

ABSTRACT

INTRODUCTION: Finally the dentist has awaken to the fact that by being a health professional, he has as primary function to take good care of the welfare of patients. In face of this challenge, the dentist starts to understand his role in the treatment of snoring and of obstructive sleep apnea and hypopnea. OBJECTIVE: The current paper has the purpose of discussing the role of this professional in the diagnosis and treatment of these diseases, most specifically of the therapy involving inter-occlusal devices, emphasizing the importance of multidisciplinarity in the reestablishment of the quality of life of the patient.

13.
J. appl. oral sci ; 19(6): 655-661, Nov.-Dec. 2011. ilus, tab
Article in English | LILACS | ID: lil-610883

ABSTRACT

OBJECTIVES: In some clinical situations, dentists come across partially edentulous patients, and it might be necessary to connect teeth to implants. The aim of this study was to evaluate a metal-ceramic fixed tooth/implant-supported denture with a straight segment, located in the posterior region of the maxilla, when varying the number of teeth used as abutments. MATERIAL AND METHODS: A three-element fixed denture composed of one tooth and one implant (Model 1), and a four-element fixed denture composed of two teeth and one implant (Model 2) were modeled. A 100 N load was applied, distributed uniformly on the entire set, simulating functional mastication, for further analysis of the SEQV (Von Mises) principal stresses, which were compared with the flow limit of the materials. RESULTS: In a quantitative analysis, it may be observed that in the denture with one tooth, the maximum SEQV stress was 47.84 MPa, whereas for the denture with two teeth the maximum SEQV stress was 35.82 MPa, both located in the region between the pontic and the tooth. CONCLUSION: Lower stresses were observed in the denture with an additional tooth. Based on the flow limit of the materials, porcelain showed values below the limit of functional mastication.


Subject(s)
Humans , Dental Abutments , Dental Stress Analysis , Dental Prosthesis, Implant-Supported/methods , Finite Element Analysis , Biomechanical Phenomena , Bite Force , Dental Implants , Models, Dental , Denture, Partial, Fixed , Dental Materials/chemistry , Elastic Modulus , Materials Testing , Stress, Mechanical
14.
ImplantNews ; 7(3): 417-423, 2010.
Article in Portuguese | LILACS, BBO | ID: lil-563046

ABSTRACT

Os implantes osseointegrados utilizados para reabilitação de edentulismo total mostram elevado grau de previsibilidade terapêutica. Entretanto, surgiu a necessidade de extrapolar as alternativas de tratamento com implantes para pacientes parcialmente edêntulos. Diante disto, vários estudos têm sido direcionados para a possibilidade ou não de unir tais implantes a dentes naturais, visto que o comportamento biomecânico destas duas estruturas apresentam peculiaridades distintas. Foram construídos dois modelos visando a simulação do comportamento mecânico de uma prótese fixa de união rígida entre dente natural e implante osseointegrado, variando a quantidade de implantes e dentes envolvidos a partir dos métodos de elementos finitos (MEF). A partir da modelagem geométrica dos modelos utilizando meio computacional, obteve-se a geração automática da malha de elementos finitos. Foi aplicada uma carga nominal de 100 N, distribuída uniformemente nas superfícies oclusais de todo o conjunto protético. Na análise dos resultados, observou-se maior deslocamento do conjunto da prótese no modelo contendo dois dentes e um implante e a tensão máxima SEQV gerada foi de 35,82 MPa. Para o modelo contendo um dente e dois implantes a tensão máxima SEQV foi de 27,11 MPa. A união entre dente e implante é previsível mecanicamente. A colocação de implantes adicionais promove maior ancoragem para o conjunto protético.


Osseointegrated implants used for rehabilitation of totally edentulous patients show a high degree of predictability. However, there is a need to extrapolate treatment options with implants for partially edentulous patients. Several studies have been focused on the possibility or not for joining such implants to natural teeth as the biomechanical behavior of these two structures have distinct features. Two computerized models were designed to simulate the mechanical behavior of a fixed union between natural tooth and osseointegrated implant, varying the number of implants and teeth involved for finite element analysis (FEA). From the geometric modeling environment using computational models, we obtained the automatic generation of finite element mesh. A 100N nominal load was uniformly distributed on the occlusal surfaces of the whole prosthesis. Results showed greater displacement of the prosthetic joint in the model with two teeth and one implant, and the maximum SEQV stress generated was 35.82 MPa. For the model containing one tooth and two implants, the maximum SEQV stress was 27.11 MPa. The union between tooth and implant is mechanically predictable. The use of additional implants promotes greater anchorage to the prosthetic joint.


Subject(s)
Jaw, Edentulous, Partially/rehabilitation , Biomechanical Phenomena , Dental Implants
15.
J. appl. oral sci ; 17(5): 515-520, Sept.-Oct. 2009. ilus, graf
Article in English | LILACS | ID: lil-531406

ABSTRACT

OBJECTIVES: This study evaluated by three-dimensional finite element analysis the tensions generated by different disocclusion patterns (canine guide and bilateral balanced occlusion) in an implant-supported mandibular complete denture. MATERIAL AND METHODS: A three-dimensional model of implant-supported mandibular complete denture was fabricated according to the Brånemark protocol. A 5-element 3.75 x 13-mm screw-shape dental implant system was modeled for this study. The implants were located in the inter-mental foramen region with 3-mm-high prosthetic components joined by a nickel-chromium framework with 12-mm bilateral cantilever covered by acrylic resin and 12 acrylic denture teeth. SolidWorks® software was used before and after processing the simulations. The mechanical properties of the components were inserted in the model and a 15 N load was established in fixed points, in each one of the simulations. Data were collected in the entire nickel-chromium framework. The results were displayed three-dimensionally as color graphic scales. RESULTS: The canine guide generated greater tensions in the region of the first implant, while the bilateral balanced occlusion generated great tensions in the entire metallic framework. The maximum tension found in the simulation of the bilateral balanced occlusion was 3.22 fold higher than the one found in the simulation of the disocclusion in canine guide. CONCLUSION: The pattern of disocclusion in canine guide is the ideal for implant-supported mandibular complete denture.


Subject(s)
Humans , Dental Occlusion , Dental Occlusion, Balanced , Dental Prosthesis, Implant-Supported , Denture, Complete, Lower , Acrylic Resins/chemistry , Alveolar Process/physiology , Biomechanical Phenomena , Computer Graphics , Computer Simulation , Chromium Alloys/chemistry , Dental Implants , Denture Bases , Denture Design , Dental Materials/chemistry , Elastic Modulus , Finite Element Analysis , Imaging, Three-Dimensional , Models, Biological , Mandible/physiology , Stress, Mechanical , Tooth, Artificial , Titanium/chemistry
16.
Braz. oral res ; 23(2): 182-189, 2009. ilus, graf
Article in English | LILACS | ID: lil-522299

ABSTRACT

A comparative and qualitative analysis of the tensions generated in the cantilever region of an implant-supported mandibular complete denture was conducted using the three-dimensional finite element method. The mechanical properties of the components were input in the model and a load of 15 N was applied in pre-determined points. In the first simulation, the load was applied on the occlusal surface of the first premolar. In the second simulation, it was applied on the first and second premolars. In the third simulation, it was applied on the first and second premolars and on the first molar. The different occlusion patterns produced similar tension distributions in the cantilever region, which followed a similar pattern in the three simulations. In all of the cases, the highest levels of tension were located in the region of the first implant. However, as the loads were dislocated distally, the tensions increased considerably. The more extensive the cantilever, the more compromised will be the infrastructure, the prosthetic components and the implants. Regardless of the length of the cantilever, the highest tensions will always be located in the region of the implant next to the load application point.


Subject(s)
Dental Occlusion , Dental Prosthesis, Implant-Supported , Dental Stress Analysis , Denture, Complete, Lower , Imaging, Three-Dimensional , Biomechanical Phenomena , Computer Simulation , Chromium/chemistry , Finite Element Analysis , Models, Biological , Mandible/physiology , Nickel/chemistry , Stress, Mechanical , Titanium/chemistry
17.
Arq. odontol ; 45(2): 61-66, 2009. ilus, tab
Article in English | LILACS, BBO | ID: lil-556545

ABSTRACT

Adhesion failure between silicone resilient liner materials and denture base resin is a common problem found in clinical practice. Bond failure results in localized unhygienic conditions at the debonded regions and causes functional failure of the prosthesis. The aim of this study was to evaluate the tensile bond strength of 2 resilient liners (auto-polymerized silicone - Permafix® and heat-polymerized silicone - Permaflex®) under the influence of a residual monomer methylmethacrylate ([MMA]R) concentration. Two polymethyl methacrylate (PMMA) specimens were prepared by implementing brass dies by means of a 3 mm thick spacer in a denture flask. Specimens (20 X 10 X 3 mm) were made by processing the resilient liners against the polymerized PMMA blocks. After polymerization, the brass spacer was removed from the mold, the PMMAblocks were trimmed, and the bonding surfaces were smoothed. The PMMA blocks were placed back into the molds and resilient liners were packed into the space provided by the brass spacer, followed by trial packing and polymerization according to manufacturer instructions. Twenty specimens...


Falha na união entre reembasadores resilientes de silicone e base acrílica da prótese é um problema encontrado na prática clínica. A falha na união resulta em condições anti-higiênicas localizadas em regiões que apresentam descolamento, além de causar perda de função das próteses. O objetivo deste trabalho foi avaliar a resistência de união de 2 reembasadores resilientes de silicone (autopolimerizável - Permafix® and termopolimerizável - Permaflex®) sob a influência da concentração do monômero residual metilmetacrilato ([MMA]R). Duas amostras de polimetilmetacrilato (PMMA) foram obtidas por meio da inclusão de matrizes metálicas separadas por um espaçador com 3mm de espessura em mufla. As amostras (20 X 10 X 3 mm) foram obtidas processando o material resiliente contra os blocos de PMMA polimerizados. Após a polimerização, removeu-se o espaçador, submeteram-se os blocos ao processo de acabamento, sendo as superfícies de união alisadas. Os blocos foram recolocados no molde e o material resiliente condensado no local...


Subject(s)
Denture Liners/adverse effects , Acrylic Resins/administration & dosage , Methylmethacrylates/administration & dosage
18.
ImplantNews ; 5(6): 627-632, nov.-dez. 2008.
Article in Portuguese | LILACS, BBO | ID: lil-523887

ABSTRACT

Atualmente, a utilização de implantes osseointegráveis vem se tornando uma prática constante entre os cirurgiões-dentistas. Uma excelente indicação desta técnica é a de reabilitação de pacientes totalmente edêntulos com uma prótese total implanto-suportada. Normalmente, estas próteses apresentam uma extensão distal, bilateral, sem apoio ou de extremo livre. Algumas das grandes preocupações em relação ao extremo livre são: seu comprimento, largura, espessura, quantidade de implantes como suporte, tamanho destes suportes e, principalmente, como funciona, biomecanicamente, este sistema. Este trabalho teve como objetivo realizar o estudo da arte deste tema controverso.


Subject(s)
Dental Occlusion , Dental Implants , Osseointegration , Biomechanical Phenomena
19.
Rev. Clín. Ortod. Dent. Press ; 6(5): 59-68, out.-nov. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-495634

ABSTRACT

A finalização ortodôntica é uma etapa do tratamento onde o ortodontista deve continuar atento aos objetivos estabelecidos no diagnóstico e planejamento de cada caso. Além disso, o profissional deve trabalhar para refinar os resultados alcançados até então, eliminando fatores que possam contribuir para a remoção dos aparelhos. Alcançar a excelência na finalização pode parecer algo simples, em alguns casos. Entretanto, em determinados pacientes, a obtenção de uma oclusão ideal pode se tornar um grande desafio. A utilização de um protocolo de finalização, coordenando todos os critérios a serem avaliados antes de se considerar o tratamento encerrado, pode facilitar o processo de finalização dentro da rotina clínica do ortodontista. Sendo assim, o objetivo desse trabalho foi realizar uma revisão crítica da literatura a respeito dos critérios objetivos de finalização do tratamento ortodôntico e propor um protocolo de avaliação dos aspectos clínicos a serem observados pelos ortodontistas durante os estágios finais da terapia ortodôntica.


Subject(s)
Orthodontics , Clinical Protocols , Treatment Outcome
20.
Rev. dent. press ortodon. ortopedi. facial ; 12(2): 96-104, mar.-abr. 2007. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-450024

ABSTRACT

OBJETIVO: duas marcas comerciais de resinas acrílicas ativadas quimicamente (RAAQ), uma de uso ortodôntico (Orto Cril®) e outra de uso protético (Jet®), polimerizadas em presença e ausência de pressão, foram analisadas em relação ao conteúdo de monômero (MMA) residual liberado em solução, em diferentes intervalos de tempo (0,083; 0,25; 1; 1,25; 2,17; 5; 9; 14 e 21 dias). METODOLOGIA: a espectroscopia de absorção no ultravioleta foi utilizada na análise de soluções aquosas de MMA, com concentrações conhecidas, visando a determinação de uma curva de calibração. Soluções aquosas contendo corpos-de-prova, confeccionados com as citadas RAAQ, foram também submetidas à análise por espectroscopia de absorção no ultravioleta. RESULTADOS E CONCLUSÕES: os resultados foram comparados aos dados da curva de calibração, visando estabelecer a concentração de MMA residual das amostras. Eles permitiram concluir que o nível de MMA residual liberado em solução foi mais elevado durante as primeiras 24 horas, havendo uma tendência à estabilização a partir desse período e que a resina acrílica de uso ortodôntico apresentou níveis mais elevados de MMA em solução do que a de uso protético, em ambas as condições de polimerização empregadas, com presença e ausência de pressão. Além disso, a presença de pressão, durante a polimerização das duas resinas, elevou a concentração de MMA em solução, não havendo, entretanto, efeito da interação entre as marcas das resinas e a presença e ausência de pressão na concentração de MMA em solução, medida ao longo do tempo. Porém, todas as três variáveis (tempo, resina e pressão) foram significantes.


AIM: Two comercial brands of auto polymerizing acrylic resins (one for orthodontics use, Orto Cril®, and the other for prosthetics use, Jet®) were analyzed concerning the amount of methyl methacrilate (MMA) monomer dissolved in solution, processed under and not under pressure, in different intervals (0.083; 0.25; 1; 1.25; 2.17; 5; 9; 14 and 21 days). METHODS: The ultra-violet absorption spectroscopy was used in the analysis of aqueous solutions of MMA, with known concentrations, in order to determine the calibration curve. Aqueous solutions containing samples made with the acrylic resins described above were submitted to ultra-violet absorption spectroscopy analysis. RESULTS AND CONCLUSIONS: The results were compared to the calibration curve data, in order to establish the MMA concentration. These results led to the conclusion that the residual MMA level dissolved in the solution was higher in the first twenty-four hours, tending to stability from this period on. Auto polymerizing acrylic resins processed under pressure showed higher levels of MMA, even though it was not noticed an interaction effect between the resins brand and the presence of pressure in the level of MMA concentration measured throughout the intervals. In spite of that, the three variables (time, resins and pressure) were of noticeable importance.


Subject(s)
Acrylic Resins , Spectrum Analysis , Methylmethacrylate , Dental Materials
SELECTION OF CITATIONS